Concrete mixer truck mixing tube does not rotate, so what is the reason? According to years of experience in small concrete mixer truck repair analysis of the following reasons.
1, the oil level is too low, not according to the requirements of the oil pipe placed.
2, suction pipe fracture or squeeze.
3, oil filter dirty.
4, connecting the pump shaft fracture.
5, the direction of rotation of the motor is not right, auxiliary pump damage.
6, the main pump high-pressure valve is damaged, or dirty.
7, release the adjustment lever, disconnect the control connection.